Home > Configuration > Load Balancing > setlbmonitor_resptimeout

setlbmonitor_resptimeout

Use this method to set amount of time for which the appliance must wait before it marks a probe as FAILED. Must be less than the value specified for the Interval parameter.

Note: For UDP-ECV monitors for which a receive string is not configured, response timeout does not apply. For UDP-ECV monitors with no receive string, probe failure is indicated by an ICMP port unreachable error received from the service.

Syntax



Parameters

monitorname

Name of the monitor.
This is mandatory parameter.

type

Type of monitor that you want to create.
This is mandatory parameter.
Possible Values : PING, TCP, HTTP, TCP-ECV, HTTP-ECV, UDP-ECV, DNS, FTP, LDNS-PING, LDNS-TCP, LDNS-DNS, RADIUS, USER, HTTP-INLINE, SIP-UDP, SIP-TCP, LOAD, FTP-EXTENDED, SMTP, SNMP, NNTP, MYSQL, MYSQL-ECV, MSSQL-ECV, ORACLE-ECV, LDAP, POP3, CITRIX-XML-SERVICE, CITRIX-WEB-INTERFACE, DNS-TCP, RTSP, ARP, CITRIX-AG, CITRIX-AAC-LOGINPAGE, CITRIX-AAC-LAS, CITRIX-XD-DDC, ND6, CITRIX-WI-EXTENDED, DIAMETER, RADIUS_ACCOUNTING, STOREFRONT, APPC, SMPP, CITRIX-XNC-ECV, CITRIX-XDM, CITRIX-STA-SERVICE, CITRIX-STA-SERVICE-NHOP, MQTT, HTTP2, DTLS, QUIC, KAFKA-AUTODISCOVER.

resptimeout

Amount of time for which the appliance must wait before it marks a probe as FAILED. Must be less than the value specified for the Interval parameter. Note: For UDP-ECV monitors for which a receive string is not configured, response timeout does not apply. For UDP-ECV monitors with no receive string, probe failure is indicated by an ICMP port unreachable error received from the service.
Default value = 2.
Minimum value = 1.
Maximum value = 20939.

units

monitor response timeout units
Default value = NSTMUNT_SEC.
Possible Values : SEC, MSEC, MIN.

Return Value

Returns simpleResult

See Also